About McIDAS         McIDAS-V        
   

SDI-104 GVAR version 20090805
Software and Instructions

Note: This package contains an updated version of the GVAR server that has not been thoroughly tested. If there are errors/bugs in the software it will impact all GOES data (not just GOES-14 data). Therefore, if you elect to install this package it should be done only on a test GOES ingestor/server (rather than on an operational GOES ingestor/server).

A new, fully tested and supported SDI-104 GVAR package is planned for later this year (NASA expects to complete checkout of GOES-14 by mid-December and hand it over to NOAA for operational use). Sites that can wait for that package should do so (rather than install this package).

SDI-104 GVAR version 20090805 contains an updated GVAR server that now stores GOES-14 calibration information inline rather than obtaining it from Block 0. As noted in the boxed text above, the updated server has not been thoroughly tested, so this 20090805 version should not be installed on opertional servers. See the SDI-104 GVAR Software Changes page to see the list of changes for all versions of SDI-104 GVAR available on the McIDAS Website.

You can obtain the SDI-104 GVAR version 20090805 files through this webpage if you purchased MUG support for your SDI-104 GVAR system or have been contacted and been given apporoval by SSEC. You will be prompted for your site's login and password when you attempt to download the installation files. If you do not know the login and password, ask your site coordinator. If you know the login and password and still have a problem obtaining these files via the web, ask your site coordinator to contact the McIDAS Help Desk by e-mail or by phone at (608) 262-2455.


Complete the following steps to obtain and install the SDI-104 GVAR software.

  1. Download the following two files to a workstation that can be accessed by your SDI-104 GVAR ingestor.

    File name Size Description
    SdiMaint.py 45 KB installation script
    adde-gvar-20090805.tar.gz 2775 KB compressed tar file containing the server binaries

  2. Log on to the SDI-104 GVAR ingestor as root and copy the files obtained in step 1 to the ingestor's /tmp directory.

  3. Stop the ingestor.
      Type: init 3

  4. Run the update script to select, and then install, SDI-104 GVAR version 20090805.
      Type: cd /tmp
      Type: /opt/bin/python ./SdiMaint.py

  5. When prompted by the script for the device or directory name, enter the following.
      Type: /tmp

  6. The script should find the adde-gvar-20090805.tar.gz file and show that version in the "ADDED" list. Confirm the update and install the software by entering the following.
      Type: yes

  7. Restart the ingestor.
      Type: init 4

McIDAS Home